Installation Instructions for Motor Torque
Module (MTM) in a 4848 Reactor Controller
560M
Warning: The Motor Torque Module can only be used in
conjunction with a Motor Control Module (MCM). The
MCM must be installed before installation of the Motor
Torque Module. For Motor Control Module installation,
see Field Installation Manual 555M.
Meter Installation in 4848 Reactor
Controller
1. Unplug the power cord of the 4848 Controller.
Remove the (2) screws located on the top/front
cover at the rear corners of the controller. Gen-
tly lift the cover forward, which is hinged at the
bottom, taking care not to apply tension on any
internal wiring.
2. If applicable, remove and discard the black hole
plug on the sloped front panel above the “PRES-
SURE” or “TEMPERATURE” text. This can be
done by pinching the clasps on the back of the
plug from the inside of the front plate. Place
“MOTOR OUTPUT” label over existing text.
3. Insert the MTM module (2084E) through the
panel cutout, from outside in, making sure the
rubber gasket is on the outside of the controller
front panel. (If wires are preinstalled, remove the
terminal connector by releasing the tabs on the
sides of the module and gently pulling the termi-
nal connector off. Reference photos below.) Slide
the white mounting bracket onto the module with
the mounting screws pointing towards the front
panel. Slide the mounting bracket forward until
it touches the controller panel. The clasps on the
mounting bracket should align with the groves
on the module. Gently tighten the screws until
the module is held into place. (If removed, reat-
tach the terminal connector.)
Terminal Connector Removal
Vue de la page 0
1 2 3 4 5 6 7 8

Résumé du contenu

Page 1 - Controller

Installation Instructions for Motor Torque Module (MTM) in a 4848 Reactor Controller560MWarning: The Motor Torque Module can only be used in conjunct

Page 2 - MTM Installation

MTM InstallationParr Instrument Company2Meter Installation in 4848 Reactor Controller (Continued)Meter Installation Diagram Side Panel RemovalThe left

Page 3

MTM Installationwww.parrinst.com37 8 9 10 11 121 2 3 4 5 62084E Pin Out(Pin 5 is blank)Picture of MTM Meter 2084E Pin OutWiring Installation in 4848 R

Page 4

MTM InstallationParr Instrument Company4Wiring Installation in 4848 Reactor Controller (Continued)1. Locate wire 1 (red) from the package. Take the

Page 5

MTM Installationwww.parrinst.com5Reattach the side panel by slipping it back on and tightening the nuts.Close the controller and replace the two screw

Page 6

MTM InstallationParr Instrument Company6ModuleKeys command:1. Press “SET” to select 2. Press return key move to next operation mode3. Up/Down arrow

Page 7

MTM Installationwww.parrinst.com7This page intentionally left blank.

Commentaires sur ces manuels

Pas de commentaire