Parr-instrument 6300 Manuel d'utilisateur Page 65

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 130
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 64
MENU OPERATING INSTRUCTIONS
6300
A
www.parrinst.com
65
Moisture as Received Entry Mode:
This key steps through the options for entering the
moisture as received correction value either manually or
through the touch screen or automatically through the
balance (USB) port.
Auto Preweigh ID Controls:
Accesses sub-menu, used to automatically assign
Sample ID numbers when a series of samples are pre
weighed ahead of the time they are actually tested.
Automatic Preweigh ID. ON/OFF toggle for this
feature.
Automatic Preweigh ID Prefix. An entry here will
be used as a prefix for all pre-weigh sample IDs.
Next Automatic Preweigh ID Number. Shows the
next Sample ID which will be assigned and is
used to enter the beginning Sample ID of any
series
Automatic Preweigh ID Increment. Establishes the
increment between samples.
REPORTING CONTROLS MENU
Report Width:
Toggle this key to set the column width of the printer
to either 40 or 80 columns. Select 40 when the 1758
Printer is used.
Automatic Reporting:
Toggles the automatic reporting ON/OFF. When ON,
preliminary reports will be generated at the conclusion
of the test and final reports will be generated as soon
as all of the thermochemical corrections are available.
When OFF, reports will only be generated by selecting
the REPORT key.
Automatic Report Destination:
Toggles to direct the reports to the Printer or the screen
display.
Individual Printed Reports:
When set to ON, will generate header information for
each report printed. In the OFF position, only one
header will be printed for a series of tests.
Edit Final Reports:
When set to ON, enables the user to revise sample
weight and thermochemical corrections of finalized
reports from the report menu.
Recalculate Final Reports:
When set to ON, causes a recalculation of stored final
reports using calibration data and menu settings cur-
rently in the Calorimeter.
Vue de la page 64
1 2 ... 60 61 62 63 64 65 66 67 68 69 70 ... 129 130

Commentaires sur ces manuels

Pas de commentaire

Sennheiser 502427 manuali

Manuali dei proprietari e guide per l'utente per Cuffie Sennheiser 502427.
We fornisce 1 manuali pdf Sennheiser 502427 per scaricare gratuitamente in base al tipo di documento: Scheda Tecnica






Più prodotti e manuali per Cuffie Sennheiser

Modelli Tipo di Documento
HD25SP Scheda Tecnica   Sennheiser HD 25-SP II, 1 pagine
05175 Scheda Tecnica   Sennheiser HD 437, 1 pagine
HD595 Scheda Tecnica   Sennheiser HD 595, 1 pagine
502767 Scheda Tecnica   Sennheiser HD 448, 2 pagine
PMX-60 Scheda Tecnica   Sennheiser PMX60 Neckband headphones, 1 pagine
HD200 Scheda Tecnica   Sennheiser DJ/Studio Headphones HD 200-V1, 1 pagine
500503 Scheda Tecnica   Sennheiser PMX 50 Street In-Ear Headphones, 4 pagine
MX55 Scheda Tecnica   Sennheiser MX 55 Twist-to-fit system, 1 pagine
5800008 Scheda Tecnica   Sennheiser PXC 150, 1 pagine
500932 Scheda Tecnica   Sennheiser CX 400, 2 pagine
RS85 Scheda Tecnica   Sennheiser RS 85-8, 1 pagine
5181 Scheda Tecnica   Sennheiser HD 62 TV, 1 pagine
MX250 Scheda Tecnica   Sennheiser MX 250, 1 pagine
002976 Scheda Tecnica   Sennheiser HD 25-1 Hifi-Stereo-Headset, 2 pagine
09926 Scheda Tecnica   Sennheiser RS 140 - RF wireless headphone, 2 pagine
HD280PROZWART Scheda Tecnica   Sennheiser HD 280 PRO, 1 pagine
PX200 Scheda Tecnica   Sennheiser PX 200, 1 pagine
04465 Scheda Tecnica      Sennheiser HD 600 Prestige Audiophile Open Headphones, 8 pagine
HMD 280 PRO Specifiche       Sennheiser HMD 280 PRO, 39 pagine
500228 Scheda Tecnica   Sennheiser PX 10, 1 pagine